Skip to content
Let's Talk

The EDGE, Anywhere

Let's Talk

-40 to 55°C

Operating Temperature

18kg

Lightweight and Compact

90m/s

Wind Resistance

Technical Mastery. Compact Innovation.

Research & Development
Edge

The Edge, anywhere. Delivers enterprise-grade performance in places traditional data centers can’t reach, from factories and farms to vehicles, retail floors, construction sites, labs, and remote research operations.

Every line, every component, and every airflow path has been meticulously orchestrated to deliver peak performance in a footprint smaller than you can imagine.

 

The below are our standardised specifications, but we engineer around you. We will work to create your system, meeting the regularity requirements you need.

Standardised Metrics & Parameters

Operating Environment Specifications

Operating temperature:
-40°C to +55°C ambient (including solar load)
Storage temperature:
From -40 to +55°C
Humidity
Up to 95%, noncondensing
Altitude
Up to 4,000 m (629 hPa) (13,000ft)

Ingress Protection

IP rating:
IP66 (JIS C0920 / IEC 60259)
Enclosure
Fully sealed
Tested
With all cables connected. No dust ingress, no water penetration

Corrosion & Environmental Resistance

Salt fog spray:
30 days
Mixed gas corrosion test:
IEC 60068260, Method 4 (21 days)
UV resistance
per GR487
Resistance
Corrosion resistant fasteners and brackets

Mechanical Robustness

Random vibration
ETSI EN 300 01924 Class 4M5
Shock:
IEC 60068227
Earthquake resistance
Multiaxis seismic testing (R4–R12 profiles)
Wind resistance
up to 90 m/s
Wind driven
rain tested per MILSTD810G Method 506.4
Mountain range with stormy conditions
Desert with hot sun
Earth from Space

Thermal & Power Characteristics

  • Sealed liquid cooling loop
  • Hybrid passive / active operation
  • Passive operation in moderate climates
  • Active cooling automatically engaged under high load or temperature

 

  • Guaranteed cold start from -40°C

 

  • Optimised airflow and thermal design
  • Potential up to 30% reduction in cooling related power consumption compared to traditional outdoor cabinet solutions

 

  • Weight: <18 kg (<40 lb)
  • Volume: <16 liters
  • Compact, low profile enclosure
  • Designed for pole, wall, and structure mounting

 

  • MTBF target: >220,000 hours
  • Zero maintenance sealed cooling loop
  • Long life seals and gaskets validated for outdoor exposure

 

  • Outdoor 5G and Open RAN edge nodes
  • Remote telecom aggregation points
  • Industrial and utility substations
  • Transportation and smart infrastructure sites
  • Harsh climate or unmanned installations

 

  • Support 16 SFPs (Small Form-factor Pluggable)
  • SFP Onsite Serviceability
  • Supports all cable diameters

Designed to comply with the following standards:

  • ETSI EN 300 019 (mechanical and transport)
  • IEC 60068 series (shock, vibration, environmental)
  • CISPR 32 / FCC Part 15 Class B (EMI)
  • IEC 610004x series (EMC immunity)
  • IEC 623681 safety
Harsh winter landscape

Reliable under extreme environmental, mechanical & electrical conditions

Edge Server is a ruggedized, sealed outdoor edge server system designed to meet Telcordia GR3108 Class 4 requirements for outside plant (OSP) telecom equipment.

The platform combines a fully sealed IP66 enclosure, hybrid liquid cooling architecture, and telecom grade mechanical design to enable cabinet less deployment in harsh outdoor environments.

Off white box on a pole in a desert, with warehouses below

Our Partners

Alps Alpine

Irish Manufacturing Research

Connect

Trinity College Dublin (TCD)

Clear pipe with blue cooling liquid in front of a blurred background

From ideas to production

Bringing your ideas to life with precision engineering and sustainable tech.
Let's Talk